Technicial Specifications
| Standby Rating | 4000(no fan)/3900 kVA | 
| Prime Power Rating | 3600(no fan)/3500 kVA | 
| Emissions/Fuel Strategy | Low Fuel, Low Emissions | 
| Voltage | 400 to 11000 Volts | 
| Frequency | 50 Hz | 
| Speed | 1500 RPM | 
| Duty Cycle | Standby, Mission Critical, Prime, Continuous | 
| Maximum Rating | 4000 kVA | 
| Minimum Rating | 3150 kVA | 
| Engine Model | C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel | 
| Bore | 175 mm | 
| Stroke | 220 mm | 
| Displacement | 105.8 l | 
| Compression Ratio | 15.3:1 | 
| Aspiration | Turbo Aftercooled | 
| Fuel System | Common Rail | 
| Governor Type | ADEM� A4 | 
| Length - Minimum | 6711 mm | 
| Length - Maximum | 8402 mm | 
| Width - Minimum | 2162 mm | 
| Width - Maximum | 3247 mm | 
| Height - Minimum | 2224 mm | 
| Height - Maximum | 3827 mm | 
| Dry Weight - Genset (minimum) | 25000 kg | 
| Dry Weight - Genset (maximum) | 30000 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
Cat ECS Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
Certifications
- EU Declaration of Conformity
 - EU Declaration of Incorporation
 - Eurasian Conformity (EAC)
 - IBC seismic certification
 
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
Standard Equipment
- 
                        Air Inlet
                        
                        
- 4 x Single element canister air cleaners with service indicator(s).
 
 
- 
                        Control Panel
                        
                        
                        
- Engine cycle crank
 
- Oil pressure (psi, kPa or bar)
 
- Digital Indicators
 
- Coolant temperature
 
- Environmental sealed front face
 
- Frequency (Hz)
 
- True RMS AC metering, 3-phase, +/-2% accuracy
 
- Text alarm/event descriptions
 
- Low coolant level
 
- Volts (L-L & L-N)
 
- Auto/start/stop control
 
- Warning/shutdown Indicators:
 
- Emergency stop pushbutton
 
- Engine cool-down timer
 
- DC volts
 
- High coolant temperature
 
- Operating hours
 
- Low oil pressure
 
- Cat ECS 100
 
- Amps (per phase & average)
 
- 4 Programmable relay Inputs
 
- Alarm acknowledge
 
- 4 Programmable relay output
 
- Failure to start (overcrank)
 
- Overspeed
 
- Lamp test
 
- 24 Volt DC operation
 
- Wall mounted controls
 
- RPM
 
 
- 
                        Cooling System
                        
                        
                        
- SCAC cooling
 
- Coolant sensors
 
- JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
 
- AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
 
 
- 
                        Exhaust
                        
                        
                        
- Dry exhaust manifold
 
- Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz
 
 
- 
                        Fuel
                        
                        
                        
- Filters x 3
 
- Secondary/tertiary fuel filters
 
- 4 Micron spin on type
 
- 10 Micron spin on type
 
- Engine mounted filters x 3
 
- Primary fuel filter water/fuel water separator
 
 
- 
                        Generators and Attachments
                        
                        
                        
- Salient pole
 
- RFI suppression
 
- Anti-condensation space heater
 
- IEC platinum Stator RTDs
 
- Form wound
 
- NEMA Class H insulation
 
- Voltage regulator
 
- Reactive droop capability
 
- Min/max Exciter limiter
 
- 3 Phase voltage sensing
 
- Exciter diode monitor
 
- 6 Leads
 
- 3 Phase brushless
 
- Right side extension box, bottom cable entry
 
- Permanent magnet excitation (PMG)
 
- Class H temperature rise at 40C ambient
 
 
- 
                        Governing System
                        
                        
                        
- ADEM A4
 
- Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
 
 
- 
                        Lube System
                        
                        
                        
- Oil drain lines and valve
 
- Gear type lube oil pump
 
- Oil filter, filler and dipstick
 
- Integral lube Oil cooler
 
- Lubricating oil
 
- Fumes disposal
 
 
- 
                        Mounting Systems
                        
                        
                        
- Rails - Engine/Generator
 
- Rubber anti-vibration mounts - shipped loose
 
 
- 
                        Starting / Charging System
                        
                        
                        
- Batteries and battery rack w/cables
 
- Dual 24 volt electric starting motors
 
- Battery disconnect switch
 
 
- 
                        General
                        
                        
                        
- SAE standard rotation
 
- Right hand servicing
 
- Paint - Caterpillar yellow with high gloss black rails
 
 
Optional Equipment
- 
                        Air Inlet Systems
                        
                        
- Single element air cleaner
 
 
- 
                        Control Panels
                        
                        
                        
- EMCP 4.4
 
- Controller and MV and HV power connection locations
 
- Load share module
 
- Controller voltage and current sensing groups
 
- Speed adjust
 
- Annunciator modules
 
- Customer interface options
 
- Generator temperature monitoring
 
- E-Stop
 
- Interconnect harness
 
- Generator harness
 
- Modbus monitoring of packages
 
- Vandal proof panel door
 
 
- 
                        Cooling System
                        
                        
                        
- Package mounted radiators
 
- Remote radiators
 
- Fuel cooler
 
 
- 
                        Crankcase Systems
                        
                        
                        
- Explosive relief valves
 
- Crankcase ventilation system
 
 
- 
                        Exhaust System
                        
                        
                        
- Front housing - Standby or mission critical
 
- Front housing - Prime or continuous
 
- Exhaust collectors/manifold
 
- Mufflers (15, 25 and 34 dBA)
 
 
- 
                        Fuel System
                        
                        
- Primary fuel filter
 
 
- 
                        Generators and Attachments
                        
                        
                        
- Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
 
- Thermostat for space heater
 
- Generator air cleaner
 
- Differential current transformers - (5, 9 and 15 kV Class)
 
 
- 
                        Instrumentation
                        
                        
- Pyrometer and thermocouples
 
 
- 
                        Lube System
                        
                        
                        
- Lube oil heater
 
- Lube oil heater with Crankcase explosion relief valves
 
- Drain group oil pans
 
- Lubricating oil
 
- Electric prelube pumps
 
- Oil filters
 
 
- 
                        Mounting System
                        
                        
                        
- Rubber anti-vibration mounts
 
- Spring type linear vibration isolators
 
- IBC vibration isolators - Shipped loose
 
 
- 
                        Special Tests / Reports
                        
                        
                        
- Generator test report
 
- PGS Test report @ 1.0 power factor
 
- PGS Test report @ 0.8 power factor
 
- Standard genset TVA (Torsional Vibration Analysis) report
 
- Custom generator TVA report
 
- Special test charge - Engine only
 
- Genset fuel consumption test
 
- Standard engine test charge
 
 
- 
                        Starting / Charging System
                        
                        
                        
- 24 Volt electric starting motor
 
- Air starting motor
 
- Air pressure regulator
 
- Starter location covers
 
- 24 Volt battery set - Dry
 
- 20, 35 and 50 Amp Battery chargers
 
- Charging alternators - Dry
 
- Jacket water heaters
 
 
- 
                        General
                        
                        
                        
- Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
 
- US aid emblem
 
- Service tools
 
- Engine barring group
 
- Manual
 
- Engine barring air powered
 
- control GP - air powered bar group