Technicial Specifications
| Maximum Rating | 900 kVA | 
| Minimum Rating | 680 kVA | 
| Emissions/Fuel Strategy | Low Fuel Consumption | 
| Voltage | 380 to 415 Volts | 
| Frequency | 50 Hz | 
| Speed | 1500 rpm | 
| Duty Cycle | Standby, Prime | 
| Engine Model | 3412C TA, V-12, 4-Stroke Water-Cooled Diesel | 
| Bore | 137.2 mm | 
| Stroke | 152.4 mm | 
| Displacement | 27.02 l | 
| Compression Ratio | 13:01 | 
| Aspiration | TA | 
| Fuel System | Pump and Lines | 
| Governor Type | ADEM™ A5 | 
| Length - Maximum | 4125 mm | 
| Width - Minimum | 1906 mm | 
| Width - Maximum | 1989 mm | 
| Height - Maximum | 1906 mm | 
| Dry Weight - Genset (minimum) | 5461 kg | 
| Dry Weight - Genset (maximum) | 5910 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
SR500 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
EMCP 4 Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
Certifications
- EU Declaration of Conformity
 - EU Declaration of Incorporation
 - Eurasian Conformity (EAC)
 
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
Standard Equipment
- 
                        Air Inlet System
                        
                        
- Air cleaner, single element canister type with service indicator
 
 
- 
                        Control Panel
                        
                        
                        
- EMCP 4.2B
 
- Customer data link (Modbus RTU)
 
- 2 Programmable relay outputs (Form C)
 
- Features include:
 
- Voltage adjust
 
- Failure to start (overcrank)
 
- Volts (L-L & L-N)
 
- Reverse power (kW) (32)
 
- Accessory module data link
 
- Over/under voltage (27 / 59)
 
- Speed adjust
 
- Low coolant temperature
 
- Oil pressure (psi, kPa or bar)
 
- Environmental sealed front face
 
- Generator temperature monitoring module
 
- DC volts
 
- Serial annunciator module data link
 
- Reverse reactive power (kVAr) (32RV)
 
- Amps (per phase & average)
 
- High coolant temperature
 
- 24 Volt DC operation
 
- Communications
 
- Power factor (per phase & average)
 
- Compatible with the following optional modules:
 
- Low coolant level
 
- Text alarm/event descriptions
 
- Digital I/O module
 
- 6 programmable digital inputs
 
- Low oil pressure
 
- Remote Serial annunciator
 
- Engine cycle crank
 
- Local annunciator
 
- Digital indication for:
 
- Over/under frequency (81 o/u)
 
- Generator phase sequence
 
- Emergency stop
 
- kVAr (per phase, average & percent)
 
- Run/auto/ stop/control
 
- Operating hours
 
- kVA (per phase, average & percent)
 
- Warning/shutdown with common LED indication of shutdowns for:
 
- Emergency stop pushbutton
 
- Frequency (Hz)
 
- coolant temperature
 
- Overspeed
 
- 4 programmable relay outputs (Form A)
 
- kW-hr (total)
 
- 2 Programmable digital outputs
 
- Remote CAN annunciator
 
- Overcurrent (50 / 51)
 
- kW (per phase, average & percent)
 
- RPM
 
- Programmable protective relaying functions:
 
 
- 
                        Cooling System
                        
                        
                        
- Radiator with guard (Sized for 50 degrees C)
 
- Coolant level shutdown
 
- Coolant drain line with valve, piped to edge of base
 
- Fan and belt guards
 
- Caterpillar extended life coolant
 
 
- 
                        Exhaust System
                        
                        
- Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
 
 
- 
                        Fuel System
                        
                        
                        
- Primary and Secondary fuel filters
 
- Fuel priming pump
 
- Flexible fuel lines terminated on base
 
- Water seperator
 
 
- 
                        Generator and Attachments
                        
                        
                        
- 2:1 Volts/Hz
 
- Busbar termination
 
- 3-phase sensing
 
- Class H insulation
 
- Reactive droop
 
- VR6 voltage regulator
 
- SR4B self excited
 
- 12 Leads
 
- Class F temperature rise
 
 
- 
                        Governing System
                        
                        
- Cat electronic governor
 
 
- 
                        Lube System
                        
                        
                        
- Oil drain line with valve, piped to edge of base
 
- Lubricating oil
 
- Oil filter
 
- Fumes disposal, piped to front of radiator
 
 
- 
                        Mounting System
                        
                        
- Base, formed steel with linear vibration isolators between base and engine-generator
 
 
- 
                        Starting / Charging System
                        
                        
                        
- 45 amp Charging alternator
 
- Battery with rack, cables
 
- Fuel shutoff solenoid
 
- 24 volt starting motor
 
 
Optional Equipment
- 
                        Air Inlet System
                        
                        
                        
- Heavy duty air cleaners
 
- Dual element air cleaners
 
- Open element air cleaners
 
 
- 
                        Circuit breakers
                        
                        
                        
- 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
 
- 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
 
 
- 
                        Control Panel
                        
                        
                        
- Generator temperature monitoring package
 
- EMCP 4.4
 
- First local annunicators
 
- Vandal proof panel door
 
- Remote custom annunicator
 
- EMCP 4.3
 
- Local discrete I/O package
 
- Common alarm/shutdown relay
 
- Ground fault relay
 
- Generator running VFC
 
 
- 
                        Cooling System
                        
                        
                        
- Radiator duct flange
 
- Jacket water heaters
 
 
- 
                        European Certifications
                        
                        
- Eurasian Conformity (EAC) mark
 
 
- 
                        Exhaust System
                        
                        
                        
- Through wall installation kit
 
- Mufflers
 
- Manifold and turbocharger guards
 
- Elbow kit
 
 
- 
                        Generator and Attachments
                        
                        
                        
- Permanent magnet excitation (PMG)
 
- Space heater
 
- Digital voltage regulator
 
- Oversize and premium generators
 
 
- 
                        Lube System
                        
                        
- Manual sump pump
 
 
- 
                        Mounting System
                        
                        
- Fuel tank base (1200 ltr)
 
 
- 
                        Special Tests / Reports
                        
                        
                        
- PGS Test report @ 0.8 power factor
 
- PGS Test report @ 1.0 power factor
 
 
- 
                        Starting / Charging
                        
                        
                        
- Oversize batteries
 
- Battery chargers
 
- Battery disconnect switch
 
- Heavy duty starting system
 
 
- 
                        Governing System
                        
                        
- Electronic load share