| Standby Rating | 1400/1250 kVA | 
| Prime Power Rating | 1275/1150 kVA | 
| Emissions/Fuel Strategy | Low Fuel Consumption | 
| Voltage | 380 to 415 Volts | 
| Frequency | 50 Hz | 
| Speed | 1500 rpm | 
| Duty Cycle | Standby, Mission Critical, Prime, Continuous | 
| Maximum Rating | 1400 kVA | 
| Minimum Rating | 1000 kVA | 
| Engine Model | 3512 TA, V-12, 4-Stroke Water-Cooled Diesel | 
| Bore | 170 mm | 
| Stroke | 190 mm | 
| Displacement | 51.8 l | 
| Compression Ratio | 13.5:1 | 
| Aspiration | TA | 
| Fuel System | Direct Unit Injection | 
| Governor Type | Woodward | 
| Length - Minimum | 5556 mm | 
| Length - Maximum | 5662 mm | 
| Width - Minimum | 1975 mm | 
| Width - Maximum | 1984 mm | 
| Height - Minimum | 2305 mm | 
| Height - Maximum | 2367 mm | 
| Dry Weight - Genset (minimum) | 10270 kg | 
| Dry Weight - Genset (maximum) | 10740 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
EMCP 4 Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
Certifications
- Telecom Lab of China (TLC)
 - EU Declaration of Conformity
 - EU Declaration of Incorporation
 - Eurasian Conformity
 
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
Standard Equipment
- 
                        Air Inlet System
                        
                        
- Air cleaner; single element canister type with service indicator
 
 
- 
                        Control Panel
                        
                        
                        
- EMCP4.2B controls includes: Emergency stop pushbutton
 
- RPM
 
- Engine cool-down timer
 
- EMCP4.2B controller includes:
 
- Accessory module data link
 
- 4 programmable relay outputs (Form A)
 
- Communications:
 
- Volts (L-L & L-N)
 
- Over/under frequency (81 o / u)
 
- Text alarm/event descriptions
 
- Auto/start/stop control
 
- Speed adjust
 
- kVA (per phase, average & percent)
 
- Overcurrent (50 / 51)
 
- Alarm acknowledge
 
- Environmental sealed front face
 
- 6 programmable digital inputs
 
- Oil pressure (psi, kPa or bar)
 
- Amps (per phase & average)
 
- Generator phase sequence
 
- 2 Programmable digital outputs
 
- Low coolant temperature
 
- Controls:
 
- Serial annunciator module data link
 
- Reverse power (kW) (32)
 
- Lamp test
 
- Coolant temperature
 
- Engine cycle crank
 
- kVAr-hr (total)
 
- 2 Programmable relay outputs (Form C)
 
- Generator mounted - rear facing
 
- 24 Volt DC operation
 
- kVAr (per phase, average & percent)
 
- Warning/shutdown with common LED indication of shutdowns for:
 
- kW (per phase, average & percent)
 
- Reverse reactive power (kVAr) (32RV)
 
- Programmable protective relaying functions:
 
- Digital indication for:
 
- High coolant temperature
 
- Low oil pressure
 
- Overspeed
 
- Over/under voltage (27 / 59)
 
- Customer data link (Modbus RTU)
 
- DC volts
 
- Operating hours
 
- Low coolant level
 
- kW-hr (total)
 
- Frequency (Hz)
 
- Emergency stop
 
- Power factor (per phase & average)
 
- Failure to start (overcrank)
 
- True RMS AC metering, 3-phase, +/-2% accuracy
 
 
- 
                        Cooling System
                        
                        
                        
- JWAC
 
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
 
- Radiator fan and fan drive
 
- Fan and belt guards
 
- Coolant drain line with valve
 
- Coolant level sensors (Not included with packages without radiator)
 
 
- 
                        Exhaust System
                        
                        
                        
- Dry exhaust manifold
 
- Flanged faced outlet(s)
 
 
- 
                        Fuel System
                        
                        
                        
- Fuel cooler; not included with packages without radiator
 
- Flexible fuel lines - shipped loose
 
- Fuel priming pump
 
- Secondary fuel filters
 
 
- 
                        Generators and Attachments
                        
                        
                        
- Generator set packages include: Regulator (CDVR)
 
- 6 Lead
 
- Min / max exciter limiter
 
- LV
 
- Reactive droop capability
 
- Random wound
 
- Exciter diode monitor
 
- KVAR/PF modes
 
- NEMA Class H insulation
 
- 50 Hz models: IEC standard hole pattern
 
- Caterpillar's digital voltage regulator (CDVR) includes:
 
- Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
 
- Busbar connections, top center mounted, top cable entry
 
- Internal excitation (IE)
 
- Winding temperature detectors
 
- Class H temperature rise at 40C ambient (125C prime/150C standby)
 
- 3 Phase brushless, Salient pole
 
- 3 Phase voltage sensing
 
- RFI suppression
 
 
- 
                        Governing System
                        
                        
- Woodward 2301A isochronous governor
 
 
- 
                        Lube System
                        
                        
                        
- Oil drain lines and valve
 
- Gear type lube oil pump
 
- Fumes disposal
 
- Oil filter, filler and dipstick
 
- Lubricating oil
 
- Integral lube Oil cooler
 
 
- 
                        Mounting System
                        
                        
                        
- Rubber anti-vibration mounts - shipped loose
 
- Rails - engine/generator/radiator mounting
 
 
- 
                        Starting / Charging System
                        
                        
                        
- 24 Volt electric starting motor
 
- Battery and battery rack w/cables
 
- Battery disconnect switch
 
 
- 
                        General
                        
                        
                        
- Paint - Caterpillar yellow with high gloss black rails & radiator
 
- SAE standard rotation
 
- RH service
 
- Flywheel and Flywheel housing - SAE No. 00
 
 
Optional Equipment
- 
                        Air Inlet System
                        
                        
                        
- Remote air inlet adaptors
 
- Air inlet protection
 
- Dual element air cleaners
 
 
- 
                        Circuit breakers
                        
                        
                        
- EMAX Circuit breakers
 
- Center posts busbars
 
- EMAX breakers connections
 
- Breaker harnesses
 
- 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
 
- Controls packaging - Enclosures
 
- Cable entry options
 
- 2000, 2500, 3200 and 4000 Amp, 3 pole, IEC rated Circuit breakers
 
- Optional busbar power connections
 
- Busbar connections
 
 
- 
                        Control Panel
                        
                        
                        
- Auxiliary boxes
 
- Customer connection mounting locations
 
- Ground (Automatically selected)
 
- Vandle proof panel door
 
- Customer Interface options
 
- Mounting group - External box clips
 
- Remote speed adjust
 
- Generator temperature monitoring
 
- Governors
 
- Annunciator Modules
 
- Local PC monitoring
 
 
- 
                        Cooling System
                        
                        
                        
- Water level switch gauges
 
- Heat exchangers
 
- Optional radiator arrangements
 
 
- 
                        European Certifications
                        
                        
                        
- EU Declaration of Conformity
 
- Eurasian Conformity (EAC) mark
 
- European Directive genset, DoI (Declaration of Incorporation)
 
- European Union Certification
 
 
- 
                        Exhaust System
                        
                        
                        
- Through-wall installation kit
 
- Muffler mounting kits
 
- Mufflers
 
- Flexible fittings
 
 
- 
                        Fuel System
                        
                        
- Primary fuel filter
 
 
- 
                        Generators and Attachments
                        
                        
                        
- 380 / 400 / 415 Volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
 
- 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
 
- Generator conversion
 
- 380/400/415volts @ 50 Hz, 3 phase, random wound, Internal excitation (IE), No. of leads = 6, pitch= 0.6667
 
- Space heater
 
 
- 
                        Instrumentation
                        
                        
- Pyrometer and thermocouples
 
 
- 
                        Lube System
                        
                        
                        
- Electric prelube pumps
 
- Oil level reg-1 shallow pan
 
- Manual prelube sump pumps
 
 
- 
                        Mounting System
                        
                        
                        
- Spring type vibration isolators
 
- IBC vibration isolators
 
 
- 
                        Protection System
                        
                        
- Explosion relief valves
 
 
- 
                        Special Tests / Reports
                        
                        
                        
- Neutral grounding connection
 
- IBC seismic Certifications
 
- Neutral ground-LV
 
- PGS Test report @ 1.0 power factor
 
- PGS Test report @ 0.8 power factor
 
 
- 
                        Starting / Charging Systems
                        
                        
                        
- Ether starting aid
 
- 24 Volt dual electric starting motor
 
- 20 Amp Battery charger
 
- Oversize battery set
 
- Jacket water heaters
 
- 10 Amp Battery chargers
 
 
- 
                        General
                        
                        
- Engine barring group