Technicial Specifications
| Continuous Rating | 2027 / 2007 ekW @ 1.0pf | 
| Fuel Type | Natural Gas, Hydrogen Blend (up to 25%) | 
| Maximum Electrical Efficiency | 45.30% | 
| Frequency | 50 / 60 Hz | 
| RPM | 1500 rpm | 
| Engine Model | G3516H | 
| Displacement | 78 l | 
| Aspiration | TA | 
| Bore | 170 mm | 
| Stroke | 215 mm | 
| Compression Ratio | 12.1 | 
| Fuel System | Natural Gas | 
| Length | 7395 mm | 
| Width | 2139 mm | 
| Height | 2402 mm | 
| Dry Weight - Genset | 18315 kg | 
Advantages and Features
Cat G3516H Gas Engine
- Robust high speed block design provides prolonged life and lower owning operationg costs
 - Designed for maximum performance on low pressure pipeline natural gas and hydrogen mixtures
 - Simple open chamber combustion system for reliability and fuel flexibility
 - Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
 - One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
 
SR5 Generator
- Designed to match performance and output characteristics of Caterpillar gas engines
 - Industry leading mechanical and electrical design
 - High efficiency
 
EMCP 4.3 Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Emissions
- Meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment
 
Proven System
- Field proven in a wide range of applications worldwide
 - Fully prototype tested
 - Certified torsional vibration analysis available
 
Full Range of Attachments
- Wide range of bolt-on system expansion attachments
 - Factory designed and tested
 - Flexible packaging options for easy and cost effective installation
 
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
Standard Equipment
- 
                        Control Panels
                        
                        
- EMCP4.3
 
 
- 
                        Air Inlet
                        
                        
                        
- Package Mounted Air Cleaner with service indicator
 
- Two-element single-stage air cleaner with enclosure and service indicator
 
 
- 
                        Cooling
                        
                        
                        
- Jacket water and SCAC driven thermostats
 
- ANSI Class 150/DN custom flange connections for JW inlet and outlet
 
- Engine driven water pumps for jacket water and after cooler
 
- 2nd stage SCAC-Cat Flange
 
 
- 
                        Exhaust
                        
                        
                        
- Center section cooled turbocharger with Cat flanged outlet
 
- Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns
 
- Dry exhaust manifolds, insulated and shielded
 
- Cat-flanged face outlet on turbocharger
 
 
- 
                        Fuel System
                        
                        
                        
- Throttle plate, 24V DC actuator, controlled by GECM
 
- Electronic fuel metering valve
 
- Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
 
 
- 
                        Ignition System
                        
                        
                        
- Electronic Ignition System (controlled by ADEM A4)
 
- Individual Cylinder Detonation Sensitive Timing (DST)
 
 
- 
                        Generator
                        
                        
                        
- Permanent Magnet Excitiation
 
- Anti-condensation space heater
 
- Winding temperature detectors
 
- SR5
 
- Reactive Droop
 
- Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
 
 
- 
                        General
                        
                        
                        
- Crankshaft vibration damper and guard
 
- Paint - Caterpillar Yellow except rails and radiators gloss black
 
- RH Service
 
- Parts book
 
- Operation and maintenance manuals
 
 
- 
                        Governing System
                        
                        
- ADEM A4 4-20mA (0-5V) Speed Input
 
 
- 
                        Starting/Charging
                        
                        
- 24V starting motors
 
 
Optional Equipment
- 
                        Air Inlet
                        
                        
                        
- Mounting brackets and piping
 
- Air cleaner with precleaner
 
- Heavy Duty air cleaner with precleaner
 
 
- 
                        Circuit Breakers
                        
                        
                        
- No UV trip or package mounted CB Wiring
 
- Frame Mounting
 
- MP-Frame 3 Pole Bottom Cable Entry or MP- Frame 6 Pole Bottom Cable Entry
 
- 4000A, 3-Pole IEC Rated
 
- 2500/3000/3200A or 4000/5000A Neutral Current Transformer Automatic Selection
 
- Lower & Upper Covers, Extension Box Roof Cover
 
- Busbar Mounting
 
- 4000A, 3-Pole UL Rated
 
 
- 
                        Control Panels
                        
                        
                        
- Remote monitoring software
 
- Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
 
- Remote RS485, 32-light Annunciator
 
- Cat Connect: Ehternet, Satellite, Cell Telematics
 
- Cross-Current Compensation Current Transformer-- 8.7/15 kV Classes
 
- RTD Module
 
- Local/Remote PC Monitorring
 
- 16 Point/32 Light Annunciator with NFPA99-110/CSA282 Configuration
 
- Remote Monitoring & Control
 
- Synchronizing module
 
- Local alarm module
 
 
- 
                        Cooling
                        
                        
                        
- Jacket water coolant heater
 
- Inlet/Outlet connections
 
 
- 
                        Exhaust
                        
                        
                        
- Flange
 
- Muffler and spark-arresting muffler with ANSI companion flanges
 
- Elbow
 
 
- 
                        Generator
                        
                        
                        
- Manual voltage control
 
- Generator air filter
 
- Low voltage extension box
 
- Medium and high voltage generators and attachment
 
- Cable access box
 
- Bearing temperature detectors
 
 
- 
                        Starting/Charging
                        
                        
                        
- 24V Battery Charger
 
- 60A, 24V charging alternator (requires engine driven pumps)
 
 
- 
                        General
                        
                        
                        
- US AID emblem
 
- Special paint order
 
- Battery diconnect switch
 
- Digital diagnostic tool
 
- Tool set
 
- Battery with cables and rack (shipped loose)
 
 
- 
                        Grid Code Compliance
                        
                        
                        
- 60 Hz: USA
 
- 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard