Technicial Specifications
| Maximum Rating | 3500 kVA | 
| Minimum Rating | 3000 kVA | 
| Emissions/Fuel Strategy | Tier 2 Equivalent - 1800 rpm | 
| Voltage | 380 to 11000 volts | 
| Frequency | 50 Hz | 
| Speed | 1800 rpm | 
| Duty Cycle | Standby, Mission Critical | 
| Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel | 
| Bore | 170 mm | 
| Stroke | 215 mm | 
| Displacement | 78.1 l | 
| Compression Ratio | 14.7:1 | 
| Aspiration | ATAAC | 
| Fuel System | Electronic Unit Injection | 
| Governor Type | Adem™5 | 
| Length - Minimum | 8513 mm | 
| Length - Maximum | 8513 mm | 
| Width - Minimum | 2640 mm | 
| Width - Maximum | 2460 mm | 
| Height - Minimum | 3342 mm | 
| Height - Maximum | 3342 mm | 
| Dry Weight - Genset (minimum) | 23000 kg | 
| Dry Weight - Genset (maximum) | 23000 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
Cat Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Cooling System
- Designed to operate in standard ambient temperatures up to 50�C (122�F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
Certifications
- EU Declaration of Conformity
 - EU Declaration of Incorporation
 - Eurasian Conformity (EAC)
 
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
Standard Equipment
- 
                        Air Inlet System
                        
                        
- Air cleaner; single element canister type
 
 
- 
                        Control System
                        
                        
                        
- Text alarm/event descriptions
 
- Emergency stop pushbutton
 
- IVR includes reactive droop capability
 
- KVAR / PF modes
 
- EMCP 4.2B
 
- 3 Phase voltage sensing
 
- Generator mounted - rear facing
 
- Generator set packages include:
 
- 24 Volt DC operation
 
- Caterpillar's voltage regulator
 
- RFI suppression
 
- Environmental sealed front face
 
- Limiter and exciter diode monitor
 
- Min / max exciter
 
- Controls:
 
- Speed adjust
 
- Alarm acknowledge
 
- Auto/start/stop control
 
- Engine cycle crank
 
- Engine cool
 
- Customizable screens
 
- PLC functionality
 
- Lamp test
 
- Load histogram feature
 
- Accessory module data link
 
- Reverse power (kW) (32)
 
- 6 Customer programmable digital inputs
 
- 3 Phase
 
- +/- 2% accuracy
 
- High coolant temperature
 
- 0 True RMS AC metering
 
- Programmable protective relaying functions:
 
- Reverse reactive power (kVAr) (32RV)
 
- Communications:
 
- Generator phase sequence
 
- Over/under voltage (27/59)
 
- Overcurrent (50/51)
 
- RPM
 
- Number of I/O varies on options selected
 
- Overspeed
 
- Serial annunciator module data link
 
- Low coolant temperature
 
- 4 Programmable relay outputs (Form A)
 
- 1 Programmable relay outputs (Form C)
 
- 3 Analog inputs
 
- Over/under frequency (81 o/u)
 
- Digital indication for:
 
- Low coolant level
 
- Failure to start (overcrank)
 
- Cat connect
 
- 1 Programmable digital outputs
 
- DC volts
 
- Operating hours
 
- Coolant temperature
 
- Oil pressure (psi, kPa or bar)
 
- Amps (per phase & average)
 
- Power factor (per phase & average)
 
- Frequency (Hz)
 
- Volts (L-L & L-N)
 
- kW (per phase, average & percent)
 
- kVA (per phase, average & percent)
 
- kVAr (per phase, average & percent)
 
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
 
- Low oil pressure
 
- kW-hr (total)
 
- kVAr-hr (total)
 
 
- 
                        Cooling System
                        
                        
                        
- ATAAC - 3516E package radiators shipped installed
 
- Certified standard PGS provided
 
 
- 
                        Exhaust System
                        
                        
                        
- Flanged faced outlet(s)
 
- Dry exhaust manifold
 
 
- 
                        Fuel System
                        
                        
                        
- Secondary fuel filters
 
- Fuel cooler; not included with packages without radiator
 
- Flexible fuel lines - shipped loose
 
 
- 
                        General
                        
                        
                        
- Right hand servicing
 
- Caterpillar yellow with high gloss black rails and radiator
 
- SAE standard rotation
 
- Flywheel and flywheel housing - SAE No. 00
 
 
- 
                        Generator and Attachments
                        
                        
                        
- NEMA standard hole pattern
 
- Medium voltage:
 
- Anti-condensation space heater
 
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
 
- Winding temperature detectors
 
- High voltage:
 
- Busbar connections, right side extension box, bottom cable entry
 
- Form wound
 
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
 
- 6 Lead
 
- Permanent magnet excitation (PMG)
 
- 3 Phase brushless, Salient pole
 
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
 
 
- 
                        Governing System
                        
                        
- ADEM A5
 
 
- 
                        Literature
                        
                        
                        
- Parts book
 
- Operation & Maintenance Manual
 
 
- 
                        Lubrication System
                        
                        
                        
- Integral lube oil cool
 
- Oil filter, filler and dipstick
 
- Oil drain lines and valve
 
- Gear type lube oil pump
 
- Lubricating oil
 
- Fumes disposal
 
 
- 
                        Mounting System
                        
                        
                        
- Rails - Engine/generator/radiator mounting
 
- Anti-vibration mounts (shipped loose)
 
- Rubber anti-vibration mounts - shipped loose
 
 
- 
                        Starting System
                        
                        
                        
- 24 Volt electric starting motor
 
- Battery disconnect switch
 
- Battery and battery rack w/cables
 
- 45 Amp Charging alternator
 
 
Optional Equipment
- 
                        Control System
                        
                        
- EMCP 4.4
 
 
- 
                        Air Inlet System
                        
                        
                        
- Single element filter
 
- Dual element air cleaner
 
 
- 
                        Cooling System
                        
                        
                        
- Standard ambient radiators
 
- Water level switch gauges
 
- Optional installed ATAAC radiators
 
- Optional installed radiators
 
- Coolant
 
- Standard ambient ATAAC radiators
 
 
- 
                        Crankcase System
                        
                        
                        
- Ventilation system
 
- No explosion relief valves
 
- Explosion relief valves
 
 
- 
                        Exhaust System
                        
                        
- Y Adapters
 
 
- 
                        Fuel System
                        
                        
                        
- Fuel priming pumps (Tier 4) - Manual or electric
 
- Primary fuel filter
 
 
- 
                        General
                        
                        
                        
- Special paint (Colors other than Caterpillar yellow or high performance paints)
 
- US aid emblem
 
 
- 
                        Generators and Attachments
                        
                        
                        
- Space heater
 
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
 
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
 
- Alternator air cleaner
 
- Thermostat for space heater
 
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
 
- Generator conversion
 
 
- 
                        Instrumentation
                        
                        
- Pyrometer and thermocouples
 
 
- 
                        Lubrication System
                        
                        
                        
- Oil level regulator
 
- Prelube pumps
 
- Lube oil in standard sump
 
 
- 
                        Mounting System
                        
                        
                        
- Puck style low efficiency isolators
 
- Spring type vibration isolators
 
- IBC vibration isolators
 
 
- 
                        Power Connections
                        
                        
                        
- Neutral ground connections
 
- Center post busbars
 
- Right side power connections
 
 
- 
                        Special Tests / Reports
                        
                        
                        
- Generator set fuel consumption test
 
- PGS Test report @ 1.0 power factor
 
- Standard engine test charge
 
- Canadian Standards Association certification
 
- Generator test report
 
- IBC Certification
 
- OSHPD Certification
 
- Fuel consumption test
 
- Torsional vibration analysis reports
 
- PGS Test report @ 0.8 power factor
 
 
- 
                        Starting and Charging
                        
                        
                        
- Starter cover
 
- Air pressure regulator
 
- 10, 20, 35 and 50 Amp Battery chargers
 
- 24 Volt battery set - Dry
 
- Jacket water heaters
 
- Air starting motors
 
- Electric starting motors
 
- Engine barring device
 
 
- 
                        Extended Service Coverage
                        
                        
- Platinum, Gold and Silver coverage