Technicial Specifications
| Minimum Rating | 150 kVA | 
| Maximum Rating | 165 kVA | 
| Emissions/Fuel Strategy | Non Regulated | 
| Voltage | 220 to 415 Volts | 
| Frequency | 50 Hz | 
| Speed | 1500 rpm | 
| Duty Cycle | Standby, Prime | 
| Engine Model | Cat® C7.1 | 
| Bore | 105 mm | 
| Stroke | 135 mm | 
| Displacement | 7 l | 
| Compression Ratio | 16.0:1 | 
| Aspiration | Turbocharged, Air to Air Aftercooled | 
| Fuel System | Inline | 
| Governor Type | Mechanical | 
| Length - Maximum | 2500 mm | 
| Width - Maximum | 1120 mm | 
| Height - Maximum | 1528 mm | 
| Dry Weight - Genset (maximum) | 1610 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
 - Accepts 100% block load in one step and meets NFPA 110 loading requirements
 - Conform to ISO 8528-5 steady state and transient response requirements
 
Cat Diesel Engine
- Reliable, rugged, durable design
 - Field-proven in thousands of applications worldwide
 - Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
 
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
 - Designed to match performance and output characteristics of Cat diesel engines
 - Robust Class H insulation
 
GCCP Control Panel
- User-friendly interface and navigation
 - Scalable system to meet a wide range of installation requirement
 - Expansion modules and site-specific programming for specific customer requirements
 
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
 - Contact your Cat Dealer for specific ambient and altitude capabilities
 
Certifications
Fully prototype tested with certified torsional vibration analysis availableOne Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
 - The generator set is fully assembled at a Caterpillar facility following our quality guidelines
 - Each generator set package is tested before leaving the Caterpillar facility
 - Cat product support, including dealer service, parts and warranty covers the entire Cat power system
 
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
 - Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
 
Standard Equipment
- 
                        Control panel
                        
                        
- GCCP Control panel
 
 
- 
                        Alternator and Alternator attachments
                        
                        
                        
- 12 Leads
 
- IP23 Protection
 
- Voltage regulator (single phase sensing)
 
- Tower panel, IP22, bottom cable entry
 
- Segregated low voltage (AC/DC) wiring panel
 
- Circuit breaker, IEC, 3 Pole, mounted in tower panel
 
 
- 
                        Governing system
                        
                        
- Mechanical or electrical governing system
 
 
- 
                        Cooling system
                        
                        
                        
- Radiator and cooling fan with guards
 
- Coolant drain line with valve
 
- Fan drive, battery charging alternator drive
 
- Caterpillar extended life coolant
 
 
- 
                        Air inlet system
                        
                        
- Air cleaner; light duty with disposable element
 
 
- 
                        Exhaust system
                        
                        
                        
- Stub pipe, gaskets, raincap & SAE exhaust flange
 
- Industrial silencer
 
 
- 
                        Fuel system
                        
                        
- Standard open set fuel tank/base
 
 
- 
                        Lube system
                        
                        
                        
- Lubricating oil
 
- Oil drain line with valve
 
 
- 
                        Mounting system
                        
                        
                        
- Captive linear vibration isolators
 
- Lifting provision and drag points
 
- Termination points for coolant and lube oil drain lines
 
 
- 
                        Starting/charging system
                        
                        
- 12V Battery with rack & cables
 
 
- 
                        General
                        
                        
- Engine and alternator pre-paint, Caterpillar yellow
 
 
Optional Equipment
- 
                        Control panel
                        
                        
                        
- GCCP Control panel
 
- Earth fault and earth leakage
 
- Emergency E-Stop with security key
 
- 4 Pole Circuit breaker
 
- Voltage and speed adjust potentiometer
 
 
- 
                        Alternator and Alternator Attachments
                        
                        
                        
- LC Frame alternator
 
- LC/M Frame alternator
 
- Space heater
 
- Permanent magnet excitation (PMG)
 
- Automatic voltage regulator
 
- Quadrature droop kit
 
 
- 
                        Enclosures
                        
                        
                        
- Level 1 and Level 2 sound attenuated enclosures
 
- Single point lifting frame
 
- Rental pack
 
- SBOX - CEE form sockets
 
 
- 
                        Alarms and Shutdowns
                        
                        
                        
- Common alarm
 
- Overload shutdown
 
- Low coolant level shutdown
 
- Low coolant temperature alarm
 
- Low fuel level alarm and shutdown
 
- High fuel level alarm
 
 
- 
                        Engine
                        
                        
                        
- Electronic governor
 
- Jacket water heater
 
- Battery charger
 
 
- 
                        Fuel system
                        
                        
- Bunded base tank sized for a minimum of 12 hours running with 110% spill protection
 
 
- 
                        Exhaust system
                        
                        
- Residential silencer 25 dBA
 
 
- 
                        Certification
                        
                        
                        
- Certificate of Conformance
 
- EAC Certification
 
 
- 
                        Extended service coverage
                        
                        
- 3, 4, 5 and 10 Years